All actions that are in red,should only be carried out by a qualified gas technician.

PRIMARY FAULT SECONDARY FAULT CAUSE ACTION
No gas ignition No spark/manual Faulty pitzo igniter Replace
Faulty H.T. lead Replace
Obstruction between electrode and burner Service refrigerator
No spark on electronic ignition Faulty switch Test,replace
No 12v Check fuse
Faulty spark generator Test,replace
Faulty H.T. lead Test,replace
Obstruction between electrode and burner Service refrigerator
No gas Blocked jet Clean jet,service Refrigerator
Blocked burner Clean burner,service refrigerator
Isolation valve switched off Turn valve on
Low Gas Output Thurmostat Failed Replace Thurmostat