Carver Cascade

All actions that are in red,should only be carried out by a qualified gas technician.

MK2

PRIMARY FAULT SECONDARY FAULT CAUSE ACTION
Not lighting on gas No gas(red light) Isolation valve off Turn valve on
Solenoid defect Listen for "clonk"when turned on.No clonk, replace module
No spark(green light may be constant) Spark generator broken Check electrode for obstruction
Replace module
Control box defect Check fuse in box
Replace box
Amber light Voltage too low Check or replace battery
Buzzing noise None Module running off charger Replace battery
No water through hot tap None Frost damage Replace inlet valve See How To.

MK2 GE

PRIMARY FAULT SECONDARY FAULT CAUSE ACTION
No hot water No 240v(no light on switch) Fuse blown Replace
R.C.D tripped Reset
None Thermostat failure Replace
Heater element faulty Check and replace See How To
Trip button out Heater on with no water in tank Reset

Water Leaks

PRIMARY FAULT SECONDARY FAULT CAUSE ACTION
Water leaks from MK2 Leak from front cover Fusible plug blown due to over heating Replace See how to.
Pressure relief valve leak/cracked Check pump(Shureflo only)
Replace relief valve
Turn through 90 degrees
See How To split pressure relief valve/inlet valve removal
Drain plug washer replace washer
Internal leak Tank damage due to frost Replace with tank kit See How To
inlet/outlet valve cracked See how to on split pressure relief valve/inlet valve removal

MK1

See MK2 chart. Parts for the MK1 are hard to come by, it is often advised to replace the MK1 with the MK2.