Space Heater

No Gas Ignition

All actions that are in red, should only be carried out by a qualified gas technician.

PRIMARY FAULT SECONDARY FAULT CAUSE ACTION
No gas ignition No spark Faulty spark generator Replace
Lead brake down Check electrode for obstruction to burner.Clean if needed
Check connection to spark generator.Replace connector,Clean.Replace lead
Lead earthing to body Replace lead
No gas Gas off Turn on gas
Rusty fire pipes Replace pipes (81,82)
Blocked jets Service fire

Flame Failure

PRIMARY FAULT SECONDARY FAULT CAUSE ACTION
Failed flame Shutting off when knob released Fault with thermocouple or thermomagnet Check thermocouple nut,should be hand tight plus 1 quarter turn
Clean probe make sure probe is in flame
Replace thermocouple or thermomagnet,thermocouple first
Flame Failer After A Short Time Thurmomagnet Fault Replace Thurmomagnet

Yellow Flame

PRIMARY FAULT SECONDARY FAULT CAUSE ACTION
Yellow or dirty flame Poor combustion Jets or burner blocked Have fire serviced.Needs cleaning

Front Covers

PRIMARY FAULT SECONDARY FAULT CAUSE ACTION
Front Cover or control spindle coming off Cover coming off Fixing springs bent outwards Bend springs inwards
Control spindle coming off Grub screw missing or loose Tighten grub screw or purchase adapted spindle